BS PD ISO/TS 17951-2:2016
Click here to purchase
BS PD ISO/TS 17951-2:2016 specifies a method for the determination of fluoride in waters, waste watersand effluents by continuous flow analysis (CFA). Any insoluble or complexed fluoride is converted tofluoride ion by an automated continuous flow distillation procedure from sulfuric/phosphoric acid.Fluoride ion in the distillate is measured using flow analysis with lanthanum alizarin complexone andspectrometric detection. This method is applicable to industrial waste waters, effluents, surface waters,ground waters, leachates. When this method is applied to the analysis of drinking water, a heater anda distillation unit is unnecessary. Some drinking water contains high concentration of aluminium andiron. In the case of drinking water, this part of ISO 17951 is appropriate to drinking water with lowinterferences. It is not applicable to samples which contain large amount of suspended matter.
In this part of ISO 17951, two working ranges are described:
- working range I: 0,1 mg/l to 1,0 mg/l;
- working range II: 1,0 mg/l to 10 mg/l.
The specification of the calibration solutions are to be adapted accordingly.
Cross References:
ISO 3696
ISO 6353-2
ISO 8466-1
ISO 8466-2
ISO 5667-3
ISO 5725-2
All current amendments available at time of purchase are included with the purchase of this document.
Product Details
- Published:
- 09/30/2016
- ISBN(s):
- 9780580941146
- Number of Pages:
- 28
- File Size:
- 1 file , 1.9 MB
- Same As:
- ISO/TS 17951-2:2016
- Product Code(s):
- 30340768, 30340768, 30340768
- Note:
- This product is unavailable in United Kingdom