API Std 650
best available scan.
Product Details
- Published:
- 11/01/1988
- File Size:
- 1 file , 18 MB
- Product Code(s):
- C65010
- Note:
- This product is unavailable in Russia, Cuba, Syria, North Korea, Belarus, Iran
best available scan.
Click here to purchase
This standard establishes minimum requirements for material, design, fabrication, erection, and inspection for vertical, cylindrical, aboveground, closed- and open-top, welded storage tanks in various sizes and capacities for internal pressures approximating atmospheric pressure (internal pressures not exceeding the weight of the roof plates), but a higher internal pressure is permitted when additional requirements are met. This standard applies only to tanks whose entire bottom is uniformly supported and to tanks in non-refrigerated service that have a maximum design temperature of 93 °C (200 °F) or less.
This standard provides industry with tanks of adequate safety and reasonable economy for use in the storage of petroleum, petroleum products, and other liquid products. This standard does not present or establish a fixed series of allowable tank sizes; instead, it is intended to permit the Purchaser to select whatever size tank may best meet their needs. This standard is intended to help Purchasers and Manufacturers in ordering, fabricating, and erecting tanks; it is not intended to prohibit Purchasers and Manufacturers from purchasing or fabricating tanks that meet specifications other than those contained in this standard.
Click here to purchase
Please note: The redline edition of this publication is a comparison of the original 12th edition to the original 11th edition, it does not incorporate any future addenda.
Please note: as a requirement of the API committee that develops this publication, some addendums may not be available as standalone files, they are simply incorporated into the base publication.
This standard establishes minimum requirements for material, design, fabrication, erection, and inspection for vertical, cylindrical, aboveground, closed- and open-top, welded storage tanks in various sizes and capacities for internal pressures approximating atmospheric pressure (internal pressures not exceeding the weight of the roof plates), but a higher internal pressure is permitted when additional requirements are met. This standard applies only to tanks whose entire bottom is uniformly supported and to tanks in non-refrigerated service that have a maximum design temperature of 93 °C (200 °F) or less.
This standard is designed to provide industry with tanks of adequate safety and reasonable economy for use in the storage of petroleum, petroleum products, and other liquid products. This standard does not present or establish a fixed series of allowable tank sizes; instead, it is intended to permit the Purchaser to select whatever size tank may best meet his needs. This standard is intended to help Purchasers and Manufacturers in ordering, fabricating, and erecting tanks; it is not intended to prohibit Purchasers and Manufacturers from purchasing or fabricating tanks that meet specifications other than those contained in this standard.
Click here to purchase
This specification covers material, design, fabrication,erection, and testing requirements for verticalcylindrical aboveground, closed and open-top, weldedsteel storage tanks in various sizes and capacities forinternal pressures approximating atmospheric pressures,except that a small internal pressure is permitted whenthe additional requirements of Appendix F are met..
Click here to purchase
API Std 650 establishes minimum requirements for material, design, fabrication, erection, and testing for vertical, cylindrical, aboveground, closed- and open-top, welded carbon or stainless steel storage tanks in various sizes and capacities for internal pressures approximating atmospheric pressure (internal pressures not exceeding the weight of the roof plates), but a higher internal pressure is permitted when additional requirements are met. This Standard applies only to tanks whose entire bottom is uniformly supported and to tanks in non-refrigerated service that have a maximum design temperature of 93°C (200°F) or less.
Interested in related datasheets? Click here!
Click here to purchase
Includes all addendums.
This standard is designed to provide the petroleum industry with tanks of adequate safety and reasonable economy for use in the storage of petroleum, petroleum products, and other liquid products commonly handled and stored by the various branches of the petroleum industry. It is intended to help purchasers and manufacturers in ordering, fabricating, and erecting tanks. Standard 650, Tenth Edition, covers material, design, fabrication, erection, and testing requirements for vertical, cylindrical, aboveground, closed- and open-top, welded steel storage tanks in various and capacities for internal pressures approximating atmospheric pressure, but a higher internal pressure is permitted when additional requirements are met. This standard applies only to tanks whose entire bottom is uniformly supported; and to tanks in nonrefrigerated service, that have a maximum operating temperature of 90 deg C (200 deg F).