This document applies to atmospheric storage tanks associated with refining, marketing, pipeline, and terminals that contain NFPA Class I or Class II liquids.

The purpose of this standard is to assist owner/operators and operating personnel in the prevention of tank overfilling by implementation of a comprehensive overfill prevention system (OPS). The goal is to receive product into the intended storage tank without overfilling or mechanical damage.

Product Details

Edition:
5th
Published:
09/01/2020
ANSI:
ANSI Approved
Number of Pages:
75
File Size:
1 file , 1.7 MB
Redline File Size:
2 files , 6.8 MB
Product Code(s):
K235005, K235005, K235005, K235005
Note:
This product is unavailable in Cuba, Iran, North Korea, Syria
API

API Std 2350

Click here to purchase
ANSI/API Standard 2350 addresses overfill protection for petroleum storage tanks. It recognized that prevention provides the most basic level of protection, thus while using both terms “protection” and “prevention”, the document emphasizes prevention. The standard”s scope covers minimum overfill (and damage) prevention practices for aboveground storage tanks in petroleum facilities, including refineries, marketing terminals, bulk plants, and pipeline terminals that receive flammable and combustible liquids.

Use of this standard is intended for storage tanks associated with marketing, refining, pipeline and terminals containing Class I or Class II petroleum liquids. Use is recommended for Class III petroleum liquids. This standard does not apply to:

  • underground storage tanks;
  • aboveground tanks of 1320 US gallons (5000 liters) or less;
  • aboveground tanks which comply with PEI 600;
  • pressure vessels;
  • tanks containing non-petroleum liquids;
  • tanks storing LPG and LNG;
  • tanks at service stations;
  • tanks filled exclusively from wheeled vehicles (i.e. tank trucks or railroad tank cars); and
  • tanks covered by OSHA 29 CFR 1910.119 and EPA 40 CFR 68 or similar regulations.

This standard recommends application of PEI Recommended Practice 600 Recommended Practices for Overfill Prevention for Shop-Fabricated Aboveground Tanks for overfill protection where applicable for aboveground tanks falling outside the scope of this document.

The purpose of this standard is to assist owner/operators and operating personnel in the prevention of tank overfills by implementation of a comprehensive overfill prevention process (OPP). The goal is to receive product into the intended storage tank without overfill or loss of containment.

This standard is one of minimum requirements. Alternate approaches or variations on the principles of this standard that provide equivalent or more robust overfill prevention are acceptable. Alternate approaches may be needed when the tank system varies from the typical configurations described in this standard. The rationale for the implementation of each overfill prevention process (OPP) should be documented and retained by the owner and operator.